and cause damage.
If 0 MPa is required, bleed the secondary side or install a 3-way valve to release the pressure
to the atmosphere.
Although the pressure control range of the product includes 0 MPa, the pressure on the secondary
side will not be completely released (the pressure of 1%FS or less of the maximum control
pressure will remain).
Working conditions for CE compliance
This product conforms to the EMC Directive and CE standard. The standard for the immunity for
industrial environments applied to this product is EN61000-6-2; the following requirements must be
satisfied in order to conform to this standard:
Conditions
The evaluation of this product is performed by using a cable that has a power supply line and a
signal line, paired to assess the product’s performance.
This product is not equipped with surge protection. Implement surge protection measures on the
system side.
About UL standard
If this product is being used as a UL-compliant product, please take care the below.
• Maximum surrounding air temperature rating of 50°C or equivalent.
• Please use the "Class 2" power supply.