Clack CI Valves Set up as SIMPLEX Softeners.
Please apply the settings in the following sequence
Selections are made using the UP & DOWN buttons until the required setting is displayed,
After each setting press NEXT to continue or press REGEN to go back one stage.
Capacities calculated at 50g CaCO3 hardness removal per litre of resin,
Vessel Size 735 835 935 1035 1044 1054 1248 1354 1465 1465 1665 1865 2160 2469 3072 3672
Media Volume (litres) 14 20 25 30 40 50 60 75 100 125 150 200 250 350 500 700
Valve Size 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1.25" 1.25" 1.5" 2" 2" 2"
Step 1, Cycle Sequence,
Press NEXT and DOWN simultaneously for 3 seconds and release.
Screen will display SOFTENING flashing
Press NEXT and DOWN simultaneously for three seconds, the screen should display SET 1, adjust to turbine setting below,
Set 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.3 1.3 1.5 2 2 2
Set (Alternating)
SET dp
Hardness
Set 1
Set 2
Set 3
Set 4
Set 5
Step 2. System Setup,
Press NEXT and DOWN simultaneously for 3 seconds and release.
SET with SOFTENING flashing should appear on screen.
Cycle 1 Backwash 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
Cycle 2 Brine dn 54 54 54 68 60 70 62 64 86 86 71 84 61 66 81 72
Cycle 3 Rinse 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
Cycle 4 Fill Kg 2 3 3.75 4.5 6 7.5 9 11.25 15 18.8 22.5 30 37.5 52.5 75 105
Cycle 4 Fill Mins 2" Only
7 (4.2g) 10 (4.2g) 14 (4.2g) 16 (5.3g)
Cycle 5 End
Set Capacity Kg 0.7 1 1.25 1.5 2 2.5 3 3.8 5 6.25 7.5 10 12.5 17.5 25 35
Set Regen
Set Time Regen
Set rLY 1 (Relay 1)
Set rLY 2 ( Relay 2)
Set Salt
Step 3, Display Settings.
Press NEXT & UP simultaneously for three seconds and release.
HARDNESS with 340 flashing should appear on screen,
Hardness
Hardness 2
Regen Day
Set Time Regen Hrs
Set Time Regen Min
Step 4, Set time of day,
Press SET CLOCK
Set hours using the up and down buttons.
Set minutes using the up and down buttons,
Software version from 332.2
An additional screen will now show if 1.5 or 2 has been selected. Select " FLo1.5 for 1.5" or FLo2 for 2" valve"
PPM
or (See note 7 for use)
Off
Backwash
Brine Draw dn
Rinse
Fill (Salt required)
End
or (See note 4 for options)
NORMAL
or (see note 5 for options)
or (see note 6 for options)
Off
Off
Alt Off
or (See note 1 for options)
or (See note 2)
Off
or (See note 3 for options)
Auto (automatic reserve calculation)
If 1.5 has been selected above an extra screen will show (Fill) select Kg
Default 2:
Set on Site (if SET REGEN is set to AUTO)
0 (not used)
14
Default :00
3.2 Softener.

Questions and Answers: