closomat LIMAPlus - Troubleshooting Common Issues; Douche Not Functioning; Irregular Douche Jet

Default Icon
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Action in event of faults
Douche does not function
Check whether main switch [1] (bottom
left of unit behind the filter cover [2]) is at
“On” (Illustration shows “off-position”).
Place the transparent checking cover [3]
sup plied between porcelain [4] and seat
[5].
Press seat [5] down at the rear with one
hand (weight on seat hinge).
Press one of the two push-keys [6] with
the other hand.
If douche still does not function:
Check fuse in power distribution box.
Possibly press Reset button on earth
leakage circuit breaker.
Press one of the two push-keys with one
hand. With the other hand simultaneously
press down the back of the seat (weight
on seat hinge).
If the douche does not function despite
presence of supply voltage:
Check whether the cistern fills again
rapidly after flushing (max. 1 min)
(Water supply sufficient?).
Douche jet irregular
Check whether water supply is available
or if it takes long for the cistern to fill
(max. 1 minute).