Water system:
Cold water connection only
Performance:
– Volume flow: min. 7 litres per minute
– Pressure: no special requirements owing
to built-in pump
Cistern capacity:
Min. 6 to max 9 litres.
The Palma and Lima models are designed as
6-litre systems and set for this at the factory.
(Your fitter can set the filling volume for any
other possible conditions.)
Boiler:
– Volume: 1.7 litres approx.
– Stand-by temperature: 36–38°C approx.
(can be set by service technician)
– Pressure:
– Reset position: unpressurized
– Working pressure: approx. 0.2 MPA
(2 bar)
– Heating time after use: 3 mins. approx.
The boiler keeps a constant stand-by
temperature, so that douche water at
body temperature is available at all times.
Alternatively: Boiler economy control (to be
activated by service technician)
Douche jet force:
– Variable externally, by pulling adjusting
lever
– Basic pressure can be set by service
technician
Douche water is not taken from the flushing
water! Exception: Modification “Separation
of push-key functions” (see page 31).
The units are constructed in accordance with
the guidelines currently effective in EC
member states for drinking water supplies
and waste water systems.
51