MAN.234 Rev.6 ENG - Use and maintenance manual S19HD page 94 of 126
Battery charger specifics
Voltage Input
100 - 240
Vac
Frequency Input
50 - 60
Hz
Maximum Output Voltage
>=60
V
Maximum Current
22
A
PWM Frequency
1
kHz
International Protection
IP20
Weight
2,2
Kg
Dimension (L*W*H)
180x310x100
mm
8.13 Maintenance of tracks
Stop the MEWP on a solid and plane ground. Lift
the counter frame and check the tensioning of
crawlers.
Remove gravel or mud stuck between the
gear wheel and the links of the track, before
proceeding with the tensioning.
The grease contained in the hydraulic track
is under pressure. If the tensioning valve is
loosened too much, it risks being expelled
under the effect of the pressure of the
grease, seriously endangering the safety of
the operator.
To tension the track, connect a pneumatic gun to
the grease pump and add grease.
To loosen the track, slowly unscrew the tensioning
valve counterclockwise for no more than one turn. If
the grease does not start to drain, slowly rotate the
track.
8.14 Consumables
Hydraulic oil:
(hydraulic tank capacity: 25 l)
Gazpromneft Hydraulic HDZ 32 o 46
32
46
Density, 15°C, kg/l
ASTM D4052
0,867
0,874
Kinematic Viscosity,
40°C, mm2/s
ASTM D445
32
46
Kinematic Viscosity,
100°C, mm2/s
ASTM D445
6,45
8,16
Viscosity Index
ASTM D2270
151
154
Pour point °C
ASTM D97
-42
-42
Flash point COC, °C
ASTM D92
216
228

Related product manuals