MAN.243 Rev.5 ENG - Use and maintenance manual S28 page 23 of 138
o MOBA console (Picture 9) positioned on the
basket;
o second AUTEC wired remote control fixed on the
basket.
It is not possible to use two different control
station at the same time.
The system will select as actual control station the first
one that will be used by the operator. Once the AUTEC
radio control station is linked, it will become the actual
control station, and in order to select a different control
station you need to turn off and back on the system by
the ignition key or any of the emergency buttons on the
machine (except the one on AUTEC radio remote
control).
3.2.1 Platform control station on the basket
(*optional)
Picture 9: platform control (operating) station.
The platform MOBA (*optional) control station (Picture 9)
on the basket has:
• two joysticks J1 and J2 (dead man commands)
for movement operations.
• a red mushroom-shaped emergency button EB
(on the right side of the control station): it stops the
machine de-energizing the electrical circuits.
The emergency button has an auto-detent
mechanical locking system; therefore, it is