10
10.8 Other alarms
10.8.1 Low battery alarm
It is activated by default, when the battery voltage is close to 3.55V, tracker will send message low
battery + latitude & longitude” to authorized numbers for 2 times at 15 minutes interval.
Turn off: lowbattery+password+space+off, response: lowbattery off ok
Turn on: lowbattery+password+space+on, response: lowbattery on ok
10.8.2 External power disconnection alarm
It is activated by default. When the external power supply is disconnected, the device will trigger
power disconnection alarm.
Turn on: extpower+password+space+on, response: extpower on ok
Turn off: extpower+password+space+off, response: extpower off ok
10.8.3 SOS alarm
Press SOS button for 3 seconds (For model G, press key on the remote control), the device will
trigger SOS alarm.
10.8.4 Movement alarm
SMS Command: move+password+space+radius, response: move ok
Cancel: nomove+password, response: nomove ok
Draw a circle with the current position of the device as the center. Once the device exceeds the radius,
the device will trigger movement alarm.
10.8.5 Over speed alarm
SMS Command: speed+password+space+speed value, response: speed ok
Cancel: nospeed+password, response: nospeed ok
When the speed exceeds the set speed value, the device will trigger over speed alarm.
10.8.6 Fuel alarm
When the vehicle's fuel consumption exceeds the normal standard while the vehicle is running, or
there is fuel leakage or fuel stealing when the vehicle is stopped, tracker will send "oil: ××%+latitude
& longitude" to the authorized numbers. The siren will sound for 20 seconds.
For reasons such as different fuel tank heights and specifications, tracker needs to set the proper
height to zero and full values in order to read the correct percentage value.
Calibrate 0%: when the fuel tank is empty
send command "oilzero+password" to the device. After
receiving it, the device will automatically calibrate the zero and reponse "oilzero ok!". At this time,
the oil value is 0%.
Calibrate 100%: Then fill up the oil tank, and then send command "oilfull+password" to the device.
After receiving it, the device will automatically calibrate 100% and reponse "oilfull ok!" At this time,
the oil value is 100%
10.9 Configure times of alarm
The times of SOS, power disconnection, oil, door, ACC alarm sending can be set.
Command: xtime+password+times value, response: xtime ok!
Send once by default.