General IconGeneral
Measurement ParametersGlucose, Cholesterol, Triglycerides, Lactate
Sample TypeCapillary whole blood
Measuring Range (Cholesterol)150-300 mg/dL (3.88-7.76 mmol/L)
Intended UseSelf-monitoring of blood glucose, cholesterol, triglycerides, and lactate levels
Measurement TimeGlucose: 12 seconds, Cholesterol: 180 seconds, Triglycerides: 180 seconds, Lactate: 60 seconds
Measuring Range (Glucose)0.6 to 33.3 mmol/L
Measuring Range (Triglycerides)6.78 mmol/L
Measuring Range (Lactate)0.8-21.7 mmol/L
Operating Conditions10 to 40 °C
Storage Conditions-25 to 70 °C
Power Supply2 AAA batteries

Summary

Introduction

The Accutrend Plus instrument

Introduces the Accutrend Plus meter and its purpose for measuring blood parameters.

CLIA Waived

Explains the CLIA waiver status of the test system and requirements.

Test principle

Describes the photometric measurement method used by the instrument.

Checking the contents

Lists the items included in the product packaging.

Safety information

Provides crucial safety precautions, especially regarding infection control.

Operating conditions

Specifies the environmental conditions required for proper instrument function.

Integrated control functions

Details the automatic checks performed by the instrument for accuracy.

About this manual

Page layout

Explains the manual's structure, page design, and symbol usage.

The Accutrend Plus instrument

Overview of instrument elements

Identifies and describes the physical components and buttons of the Accutrend Plus meter.

Display and symbols

Explains the meanings of various icons and messages displayed on the instrument screen.

Power

Covers battery operation, power-saving features, and battery replacement guidelines.

Operating the instrument

Inserting batteries

Step-by-step guide on how to insert and replace the instrument's batteries.

Instrument settings

Brief overview of the instrument settings

Provides a summary table of all configurable settings for the instrument.

General procedure for setting up the instrument (set mode)

Outlines the general process for accessing and changing instrument settings.

Setting the date format

Details how to select the desired date display format (e.g., MM-DD-YY or DD-MM-YY).

Setting the date

Guides the user through inputting the current year, month, and day.

Setting the time format

Explains how to choose between 12-hour and 24-hour time displays.

Setting the time

Provides instructions for setting the current hour and minutes.

Setting the beeper

Describes how to enable or disable audible beeps for instrument events.

Performing a measurement

What you need

Lists all necessary items required for performing a measurement.

Brief overview of the steps to be carried out

Provides a concise summary of the entire measurement process.

Important notes

Highlights critical points and precautions to ensure accurate measurements.

Test strips

Describes the components and types of test strips used with the instrument.

Code strips

Explains the function and proper use of code strips for instrument coding.

Switching on the instrument

Details how to power on the Accutrend Plus meter.

Inserting the code strip

Provides instructions on correctly inserting the code strip into the instrument.

Switching the code display

Explains how to view stored code numbers for different test parameters.

Sample material

Specifies the type and volume of blood sample required for measurement.

Performing measurements in the professional sector

Offers specific safety guidelines for healthcare professionals using the device.

Preparing to perform a measurement

Outlines the preliminary steps before conducting a blood measurement.

Performing a measurement

Detailed instructions for executing a blood glucose or cholesterol measurement.

Recommendations for the collection and measurement of capillary blood

Provides advice on collecting a suitable blood sample from the fingertip.

Blood collection

Step-by-step guide on how to perform the lancing procedure.

Blood application in the instrument

Describes the correct method for applying blood to the test strip within the instrument.

Alternative blood application outside the device

Explains an alternative procedure for applying blood samples.

Checking the applied blood

Instructions on verifying that the correct amount of blood has been applied.

Starting the measurement

Details how to initiate the measurement after applying the blood sample.

Display of results

Explains how to interpret the measurement results displayed on the screen.

Flagging measurements

Describes how to add event flags or control indicators to recorded measurements.

Quality control recommendation

What you need

Lists the necessary items for performing control tests.

Preparing to perform a control test

Outlines the steps to prepare for a quality control check.

Performing a control test

Step-by-step guide for conducting a control measurement using control solutions.

Applying the control solution

Details the correct method for applying control solutions to the test strip.

Starting the measurement

Initiates the measurement process for control solutions.

Display of results

Explains how to check and interpret the results of a control test.

Memory

Displaying stored measured values

Instructions on how to access and view previously recorded measurement data.

Cleaning

Cleaning the outer instrument components

Guidelines for cleaning the exterior surfaces of the meter.

Cleaning the inner instrument components

Procedures for cleaning the internal parts of the instrument.

Cleaning the optical measuring system

Instructions for cleaning the critical optical sensor area.

Error messages

Error messages

Provides a comprehensive list of error codes and their meanings with solutions.

Further information

Ordering information

Lists available accessories and consumables with their catalog numbers.

Product specifications

Operating conditions and technical data

Detailed technical specifications and operating parameters of the instrument.

Sample material

Information regarding the required sample type and volume.

Storage and transport conditions

Specifies the correct conditions for storing and transporting the instrument.

Disposal of instrument, strips, lancets and batteries

Guidelines for the safe and compliant disposal of the device and its components.

Service information

Contact details for technical assistance and customer support.

Warranty

Accutrend Plus Meter Limited Warranty