2201R Mobile Tester User Guide
Chapter 3 Performing manual tests and measurements in GSM mode
47090/322
Copyright © 2015 Aeroflex Limited. All rights reserved.
49
Group call BS CALL
1. Set the standard test parameters (channel numbers and so on). Enter the group call test parameters:
Group ID (up to 9 digits)
Priority level (0 through 4, A or B)
2. Press the BS Call soft key to initiate a group call from the 2201R.
3. The 2201R now displays the VGCS BS CALL active. This GUI shows the group call test parameters used to
transmit the group call to the mobile phone. On the DUT check whether a continuous tone can be heard.
4. Stop the test by pressing the BS Release soft key on the GUI.