EasyManuals Logo

COBHAM 2201R User Manual

COBHAM 2201R
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
2201R Mobile Tester User Guide
Chapter 3 Performing manual tests and measurements in GSM mode
47090/322
Copyright © 2015 Aeroflex Limited. All rights reserved.
51
Emergency Call BS CALL
1. Set the standard test parameters (channel numbers and so on). Enter the emergency call test parameters:
Group ID: 299
Priority level: 0
2. Press the BS Call soft key to initiate an emergency call from the 2201R.
3. The 2201R now displays VGCS BS CALL active. This GUI shows the group call test parameters used to transmit
the group call to the mobile phone. On the DUT check for the emergency call alert. After the alert check whether
a continuous tone can be heard.
4. Stop the test by pressing the U2U Info soft key on the GUI.
NOTE
As the system waits for Emergency call acknowledgment, a pop-up appears on the screen -
'Emergency call acknowledgment (REC ACK) is expected'. If the pop-up stays for a while and you
want to terminate the process, press ESC on the keyboard. In case you face any issue after
pressing ESC key, please go to the main screen of 2201R and re-execute the scenario.