Chapter 3: Service & maintenance
Troubleshooting 19
33333
Service & maintenance
BITE events (warning sign)
BITE events are shown in the event list. The following table shows
suggestions how to deal with the events.
BITE ID
(HEX)
System component
symptom
Remedy
8301
8302
ADU GPS module has
no connection
ADU GPS module has
no fix
Restart the terminal and see
below.
Inspect the ADU and check all
cables.
Compare position shown on
Status page with vessel’s main
GPS.
8401
8402
ADU Temperature
above warning level
ADU Temperature
above critical level
The system will automatically
decrease the transmit
performance on temperature
warnings.
On detection of critical
temperatures the system will
protect itself by powering off the
ADU. After a cool down period
(30 minutes) the system will
automatically restart.
8403
8404
8405
8406
8407
8408
8409
840A
ADU internal voltage
errors.
Contact your service partner.