98-175666-C Appendix F: Event messages F-7
List of events
08841-0 ADM ERROR Tuner lock The internal tuner PLL was unable to lock.
(!V,!T)
08842-0 ADM WARNING GSC demodulator The GSC demodulator has reported an error.
(!V,!T)
08843-0 ADM WARNING DVBS demodulator The DVBS demodulator cannot be initialised
and loaded correctly. (!V,!T)
08844-0 ADM WARNING BUC voltage out of
range
The BUC voltage is out of range. (!V,!T)
08845-0 ADM WARNING LNB voltage out of
range
The LNB voltage is out of range. The LNB might
be switched off to protect the power supply
circuitry. Reactivate satellite profile to try again,
check LNB cable and surroundings if the
problem persists. (!V,!T)
08846-0 ADM WARNING AIM-O supply
voltage out of
range
Supply voltage measured at AIM-O is not within
expected range (!V,!T)
08847-0 ADM WARNING AIM-O Master PLL
lock
The AIMO master PLL has lost lock. Check the
input reference signal. (!T)
08848-0 ADM WARNING TX Calibration
missing
Tx calibration not performed. (!T)
08880-0 ADM WARNING WLAN configuration
error
Configuration of WLAN module failed. (!V,!T)
08881-0 ADM WARNING DHCP Client
address
An IP address was received from an external
DHCP server that overlaps another VLAN. Traffic
on these VLANs may be unpredictable.
Reconfigure the server or IP settings of that
VLAN.
08A00-0 ADM WARNING GX Core Module fan There is a problem with the Core Module fan.
Check/clean and replace if necessary. (!V,!T)
08A01-0 ADM WARNING GX Core Module
heater
There is a problem with the Core Module heater.
Check and replace if necessary. (!V,!T)
08A02-0 ADM WARNING GX Core Module
temperature
The Core Module temperature is out of range.
This may affect performance, and the Core
Module will be shut down if the situation gets
worse. If the "GX core module heating" event is
also present, the internal heater is currently
warming up the unit to its operational
temperature. (!V,!T)
ID Module Type Description Explanation
Table F-1: Event messages (Continued)

Table of Contents

Other manuals for COBHAM SAILOR XTR GX-R2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the COBHAM SAILOR XTR GX-R2 and is the answer not in the manual?

COBHAM SAILOR XTR GX-R2 Specifications

General IconGeneral
BrandCOBHAM
ModelSAILOR XTR GX-R2
CategoryAntenna
LanguageEnglish

Related product manuals