Getting started
40 2110 SSB Transceiver Getting Started Guide
1 If you made the call in:
• an ALE/CALM network, wait until a message informs
you that the call has been successful (this means your
call has been automatically answered by the other
station)
• a Codan Selcall network, wait until a message informs
you that the call has been sent and listen for audible
beeps transmitted from the other station
1 Hold down PTT then speak.
Release PTT when you have finished speaking.
1 To end the call, press SCAN.
If the transceiver was scanning prior to the call it
resumes scanning.
NOTE
If you have the MIL-STD-188-141B ALE
option installed and made the call using a
special ALE address syntax, you will be
able to send data within the established link
by pressing CALL and following the
prompts.