FAULT FINDING GUIDE
FAULT
POSSIBLE CAUSE
ACTION
FATAL I
2
C ERROR
Displayed
Keypad does not bleep
Drinks cold
No motor operation
Machine inoperable.
no display
(a) Electrical noise
(b) MPU Board fault
(c) Software error
(a) Keypad damaged
(b) Keypad disconnected
(c) MPU Board fault
(a) Heater fuse blown
(b) Thermal cut-out tripped
(c) Desired temperature
incorrectly set
(d) Excessive scaling in heater
tank
(e) Solid state relay fault
(f) Low cut-out in program
incorrectly set
(g) Temperature probe wet
(a) Jammed motor
(b) Power Supply failure
safety trip
(a) Power Supply failure
(a) Check motors
(b) Replace MPU Board
(c) Reset power
(a) Replace keypad
(b) Reconnect
(c) Replace MPU Board
(a) Check and replace
(b) Reset trip
(c) Check desired temperature
setting
(d) Check tank and descale if
necessary
(e) Check relay
(f) Reset low cut-out setting
(g) Dry probe and check
for leaks.
(a) Check motor operation
(b) Reset power
(a) Replace Power Supply
Board
FAULT
POSSIBLE CAUSE
ACTION

Other manuals for COFFEtek Neo +

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the COFFEtek Neo + and is the answer not in the manual?

COFFEtek Neo + Specifications

General IconGeneral
BrandCOFFEtek
ModelNeo +
CategoryVending machines
LanguageEnglish