This resets all advanced mode override periods to zero, effectively making advanced
mode behave identically to the basic economy timed event. Note that it does not turn
off advanced mode, neither does it cancel learning mode.
20. ECONOMY DELAY
This configures the time, in minutes, for which the machine should maintain full
temperature following an override.
21. PIR SENSITIVITY
Sets how much activity detected by the PIR is required to trigger an override. When
set to ANY PIR ACTIVITY, a single read of activity is sufficient to trigger an override.
When set to any other value (1-16), a store is maintained of the most recent 16 reads
of PIR status. Only when sufficient of them have shown activity will the override state
be activated.
Depressurise Coffee Brewer
42. This feature allows an engineer to depressurise a pressurised coffee brewer during
testing/usage. By pressing ENTER on this section in the machine’s menu, it allows air to be
slowly released from the brewer preventing it from spraying hot liquid over the machine.