ARJ21-SVV19-13120-00
RampServicingOperation
Instruction
Precautionsandlimitsfortherefuel/defueloperation-Maintenance
Precautions
1.CommonInformation
A.Thisprocedureprovidessafetyprecautionsthatmustbeobeywhenrefueling/defuelingtheaircraft.
(1)EmergencyProcedures
(2)Fuelspillprocedure
(3)Refuelingwhilepassengersareonboard
(4)Airplanesystemprecautions
(5)Airplaneseparationdistancelimits
(6)Electrical/electronicsystemsseparationdistancelimits
(7)Fuelspecications
(8)Fuelservicingequipmentprecautions
(9)RefuelingZone
(10)RefuelingPrecautions
B.EachoperatorshouldcomplywiththeCAACRegulationsregardingcivilaircraftrefuelinganddefu-
eling.
C.Makesureallproceduresusedduringtherefuelingoperationgivesufcientprotectiontopersonsand
equipment.
2.PreliminaryRequirements
WorkZones
ZoneLocation
140CenterWing-STA560.722toSTA648
520LeftOuterWingBox
620RightOuterWingBox
3.Procedures
A.Procedure
(1)EmergencyProcedures
(a)Obeyallreprotection,rescueandfuelspillemergencyproceduresprovidedbytheairport
andoperator.Emergencyproceduresincludethesesubjects:
1)Locationofemergencyfuelshutoff
2)Airportredepartmentphonenumbers
3)Fuelspillprocedure
4)Locationanduseofreextinguishers
ARJ21-A-13-12-18-00A-913A-A
Issue001,2023-01-29
Applicableto:ALL