ARJ21-SVV19-13120-00
RampServicingOperation
Instruction
SwitchNamePosition/Status
LHTANKCLOSEDOn
RHTANKCLOSEDOn
DEFUELINGOPENOff
(h)EnterthedesiredtotalquantityoffuelwiththeINCR/DECRTswitchontherefuel/defuel
panel.
NOTE:
Evenifthescheduledrefuelingquantityforthisightisthesamewiththepreselect
fuelquantityshownontherefuel/defuelindicator,itisstillnecessarytooperatethe
INCR/DECRTswitchtosetthetargetrefuelingquantity.
CAUTION:CHECKTHELEFTANDRIGHTFUELTANKSFORFUELOVERFLOWDURING
THEREFUELINGPROCESS.EXCESSIVEREFUELINGWILLCAUSEFLOW-
INGOFUNWANTEDFUELTOTHENACAVENTANDDAMAGETOTHEAIR-
FRAMESTRUCTURE.
(i)SettheLHTANKREFUELINGandRHTANKREFUELINGswitchestotheOPENposition.
MakesurethattheLHTANKandRHTANKrefuelshutoffvalveCLOSEDannunciatorsare
offandtherefuelingoperationisstarted.
(j)Whenthetargetfuelquantityisreached,therefuelingoperationstopsautomatically.Make
surethattheLHTANKandRHTANKrefuelshutoffvalveCLOSEDannunciatorsareon.
(k)Stoptherefuelingoperation.
(l)SettheLHTANKREFUELINGandRHTANKREFUELINGswitchestotheCLOSEDpo-
sition.
(m)MakesurethatthePOWERSELECTIONswitchisintheNORMALposition.
(n)Rotatetheshutoffvalvehandleoftherefuelnozzletotheclosedposition,disconnectthe
refuelnozzlefromtherefuel/defueladapter.
(o)Installtherefuel/defueladaptercapontherefuel/defueladapter.
(p)Removeanyspilledfuelattherefueladapter,withadrycottonclothwipe.
(2)ManualPressureRefueling
(a)Makesurethattherelatedswitchesontherefuel/defuelcontrolpanelaresettothese
positions:
SwitchNamePosition/Status
REFUELSELECTIONMANUAL
LHTANKREFUELINGCLOSED
RHTANKREFUELINGCLOSED
DEFUELINGCLOSED
(b)Makesurethattherelatedannunciatorsontherefuel/defuelcontrolpanelshowasfollows:
ARJ21-A-13-12-18-03A-211A-A
Issue001,2023-01-29
Applicableto:ALL
Page3of6