K-series OEM Board User Guide
2. Send command Log reglista to check the registration status. It will show the number
and list of activated functions (ZONEGLOBAL function as an example in the
following figure)
5.11 Event Marker
Markcontrol
MARKCONTROL signal switch [polarity] [timebias [timeguard]]
Description
The signal only supports the key words “mark1”; switch supports the key words “enable”
and disable”; polarity supports the key words “positive” and “negative, which
separately represent positive pulse” and “negative pulse”; timebias and timeguard
parameters cannot be set by now.
The settings can be saved by saveconfig command and the markcontrol status can be
checked by log sysconfig command.
Example
markcontrol mark1 enable negative 0 0
Log marktimea onnew //Time of mark input event
Log markposa onnew // Position at time of mark input event