34
SYSTEM OPTIONS
2-SPEED FILTER PUMP CONTROL
If your system incorporates a 2-Speed Filter Pump, the Cp3000 has been designed to provide you with the maximum
energy- efficient usage of this feature. See 2-SPEED FILTER PUMP CONTROL in the Installation section for details.
Although your Pool Builder may have adjusted the two speed control circuitry to your specific requirements, the
Cp3000 typically switches the pump to high speed under any of the following conditions:
1. For five minutes when the pump is first turned on. This features establishes proper flow through the system, and
packs the filter grids. After five minutes, the pump will automatically switch to low speed.
2. Whenever the pool cleaner (if applicable) is running. This provides sufficient flow for the pool cleaner to operate
effectively.
3. During spa circulation to increase the jet action.
4. Whenever the heater is on. Larger heaters may require high speed circulation for proper operation.
5. Whenever your solar system (if applicable) is operating. This provides high flow rate through your solar panels,
which ensures the most efficient usage of the available solar energy.
6. Whenever a dedicated Equipment Key is pressed.
SPA WATERFALL CONTROL
If your spa water level is elevated above that of the pool, it is possible to circulate the pool water back to the spa, thus
creating an overflow (waterfall effect) from the spa to the pool. This effect will cease during spa circulation or you
turn on your “booster pump” pool cleaner (if applicable).
This feature can be activated from Equipment Key #2 (Aux2 circuit) at the Cp3000 Controller. See SPA
WATERFALL CONTROL SWITCH for details.
FREEZE PROTECTION
It is possible to protect the plumbing and equipment from possible freeze damage by activating the filter pump and
other pumps whenever the temperature falls to 35° Fahrenheit. Your Pool builder may have already activated this
feature. See FREEZE PROTECTION SETTINGS for details.
Note: This type of freeze protection will not provide circulation of water through your solar panels. Solar freeze
protection must be accomplished by other methods. See Plumbing Requirements for details.