- 16 -
puts whenever this temperature is reached. This function may be
especially useful, for safety reasons, for underoor and electrical
heating systems. If you wish to use the sensor to measure oor
temperature, we propose to put the temperature sensor in a short
copper pipe and sink it into the oor so that it can be replaced
easily when a breakdown occurs.
If you connected also a oor temperature sensor to your thermos-
tat and you have chosen the sensor of the thermostat so that the
main sensor is the built-in temperature sensor, and you use the
oor temperature sensor as a safety sensor (2/In-scontrol,Out-s
limit) (see Sub-chapter8.1) then you can check the temperature
measured by the oor temperature sensor in the application at the
place shown in Figure 2. You can view this temperature on the
thermostat by touching and
icons at the same time. Now
the Floor Temperature appears instead of the Room Temperature
on the display of the thermostat. The temperature displayed on the
thermostat will return to the Room Temperature approximately 10
seconds after you touched any button of the thermostat.
6.3.Connectiontotheelectricalnetwork
The product should be connected to the 230 V network through
a two core cable. Power supply should be connected to points N