- 36 -
and 2 switches per day for 2 days of the weekend
6+1mode: setting 6 switches per day from Monday till
Saturday and 2 switches on Sunday
7+0mode: setting 6 switches per day for every day of
the week
If you do not need all adjustable switches on certain days (e.g.
only 4 switches is required on working days), you can eliminate
unnecessary switches by setting their time and temperature to
the time and temperature of the last switch you want to use.
10.2.2.Descriptionofthestepsofprogramming
Usingphoneapplication:
a) To enter programming mode touch the schematic illustra-
tion of programming: at the bottom of
the screen belonging to the thermostat for approximately 3
seconds. Then the screen for programming appears on the
display.
b) The indication of the currently selected programming mode
is located at the top of the screen for programming, beside
the legend LOOP. Touching this, you can switch between
programming modes as follows:
- 12345,67: 5+2 mode

Table of Contents