- 29 -
so that the main sensor is the built-in temperature sensor, and
you use the oor temperature sensor as a safety sensor (2 /
In-scontrol,Out-slimit) then you can check the temperature
measured by the oor temperature sensor in the application at
the place shown in Figure 2. You can view this temperature
on the thermostat by touching and
icons at the same
time. Now the Floor Temperature appears instead of the Room
Temperature on the display of the thermostat. The temperature
displayed on the thermostat will return to the Room Tempera-
ture approximately 10 seconds after you touched any button of
the thermostat.
8.2. Setting oor temperature limit and corresponding
switchsensitivity
If you have chosen setting of internal and oor sensors (2/In-s
control, Out-s limit) at menu item “Selecting temperature
sensor” (SEN), a maximum temperature can be set for the o-
or temperature sensor. When the temperature measured by the
oor temperature sensor reaches the set value, the thermostat
disables its outputs (switches them out regardless of the tempe-
rature set on the thermostat) until the temperature cools down
below the set temperature, considering the switch sensitivity
set for the oor temperature (DIF). This means that when the