UT-4500 Series C- and Ku-Band Up Converters MN/UT4500.IOM
Front Panel Operation Revision 3
6–19
Conv Temperature = OK
High Speed Bus = OK
Use the  keys to page between screens. Press ENTER or CLEAR to return to
the previous menu.
6.2.5.2 (FAULTS:) STORED
VIEW CLEAR-ALL
Use the keys to select View or Clear-All. Press ENTER.
6.2.5.2.1 (FAULTS:) STORED VIEW
If you select View and no faults exist in the stored faults log, the system displays
this message:
No Stored Faults.
Otherwise, stored faults log entries display as per this example:
Log05 01/23/11 09:27:15
Fault HSB
Use the  keys to page between screens. The faults log can store up to 100
faults. When a fault condition occurs, the unit assigns a number to the fault (in
the order received), date- and time-stamps the fault, and provides a condensed
description of the issue. When the fault condition clears, this action is recorded
in the same fashion as the fault was originally recorded, as shown per this
example:
Log09 01/23/11 10:45:35
Clear HSB