EasyManua.ls Logo

Comtech EF Data UT-4505 - ATT (Attenuation); CLD (Cold Start); MUT (RF Mute)

Default Icon
208 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UT-4500 Series C- and Ku-Band Up Converters MN/UT4500.IOM
Serial Interface Operation Revision 3
8–21
8.7.3.3 ATT (Attenuation)
Use ATT to set or return the attenuation value. The default value is 10.00 dB.
Description
Details
Set Attenuation:
<DEV/ATT_ yy.yy{cr} where:
yy.yy = 00.00 to 25.00 dB in 0.25 dB steps.
Confirmation:
>DEV/ATT_yy.yy{cr}{lf}]
Return Attenuation:
<DEV/ATT_{cr}
Confirmation:
>DEV/ATT_ yy.yy{cr}{lf}]
8.7.3.4 CLD (Cold Start)
This command is NOT AVAILABLE in redundant systems.
Use CLD to mute the output signal for a predetermined time 15 minutes
following Power-Up to ensure a stable reference oscillator. The default is OFF.
Description
Details
Set Cold Start:
<DEV/CLD_xxx{cr} where:
xxx = ON or OFF
Confirmation:
>DEV/CLD_xxx{cr}{lf}]
Return Status:
<DEV/CLD_{cr}
Confirmation:
>DEV/CLD_xxx{cr}{lf}]
8.7.3.5 MUT (RF Mute)
Use MUT to set or return the RF mute state. The default is ON (output is muted).
Description
Details
Mute Output:
<DEV/MUT_xxx{cr} where:
xxx = ON or OFF
Confirmation:
>DEV/MUT_xxx{cr}{lf}]
Return Mute Status:
<DEV/MUT_{cr}
Confirmation:
>DEV/MUT_yyy{cr}{lf}]
yyy = ON/OFF/COLD

Table of Contents