EasyManua.ls Logo

Comtech EF Data UT-4505 - Baud Rate; Asynchronous Character Format; Character Set; Response Timeout

Default Icon
208 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UT-4500 Series C- and Ku-Band Up Converters MN/UT4500.IOM
Serial Interface Operation Revision 3
8–6
8.5.2 Baud Rate
The supported baud rates are 1200, 2400, 4800, 9600, 19200, and 38400 baud.
The default baud rate is 9600.
8.5.3 Asynchronous Character Format
The default asynchronous character format is 8-N-1: 8 data bits; no parity; 1 stop
bit.
8.5.4 Character Set
The command syntax uses the printable ASCII character set.
8.5.5 Response Timeout
A minimum of 500 milliseconds is provided before declaring a “no response”
instance, at which time the command is re-transmitted.
8.5.6 Bus Inactivity Requirement
Comtech EF Data recommends that you provide a minimum of 50 milliseconds
bus inactivity between the receipt of a response from an addressed converter
and issuing the next command on the serial bus.