Refilling the Desiccant Tank (continued)
7 Vibrate the tank for 15 minutes. (Important, no further settling can
occur.)
8 Reinstall the screen cap. Place the cap on the band. Install one of the 1/4-20
nuts on the center post and tighten. Do not over-tighten. Install the second 1/4-
20 nut and tighten.
9 Reinstall the tank end plate. Place the end plate on the tank and tighten the
six 10-32 screws.
10 Shake the tank beside your ear. If properly filled, you will not be able to
hear any desiccant rattling in the tank.
11 Reinstall the desiccant tank on the carousel. See “Replacing Desiccant
Tanks.
IMPORTANT: After filling with
fresh desiccant, vibrate the tank
for at least 15 minutes.