66 67
Contour
®
next blood glucose monitoring system
TECHNICAL INFORMATION
High blood glucose (Hyperglycaemia):
frequent urination
excessive thirst
blurred vision
increased fatigue
hunger
Ketones (Ketoacidosis):
shortness of breath
nausea or vomiting
very dry mouth
For additional information and a complete list of symptoms, contact
your health care professional.
Specications
Test Sample: Capillary and venous whole blood
Test Result: Referenced to plasma/serum glucose
Sample Volume: 0.6 μL
Measuring Range: 0.6 mmol/L33.3 mmol/L of glucose in blood
Countdown Time: 5 seconds
Memory: Stores most recent 800 test results
Battery Type: Two 3-volt CR2032 or DL2032 coin cell batteries,
225 mAh capacity
WARNING
If you are experiencing any of these symptoms, test your
blood glucose. If your test result is under 2.8 mmol/L or
above 13.9 mmol/L, contact your health care professional
immediately. If the blood glucose reading is 13.9 mmol/L or
greater, check your ketone levels.
1
Battery Life: Approximately 1000 tests (1 yr. average use,
3 tests per day)
Meter Operating Temperature Range:
Control Testing Temperature Range:
Meter Operating Humidity Range: 10% RH93% RH
Test Strip Storage Conditions:C30°C, 10%80% Relative
Humidity (RH)
Dimensions: 78.5 mm (L) x 56 mm (W) x 18 mm (H)
Weight: 53 grams
Sound Output: 45 dB(A)–85 dB(A) at a distance of 10 cm
Radio Frequency Technology: Bluetooth Low Energy
Radio Frequency Band: 2.4 GHz–2.483 GHz
Maximum Radio Transmitter Power: 1 mW
Modulation: Gaussian Frequency Shift Keying (GFSK)
Electromagnetic Compatibility (EMC): The
Contour next
meter complies with the electromagnetic requirements specied in
ISO 15197:2013. Electromagnetic emissions are low and unlikely
to interfere with other nearby electronic equipment, nor are
emissions from nearby electronic equipment likely to interfere with
the Contour next meter. The Contour next meter meets the
requirements of IEC 61000-4-2 for immunity to electrostatic discharge.
Avoid use of electronic devices in very dry environments, especially
if synthetic materials are present. The Contour next meter meets
the requirements of IEC 61326-1 for radio frequency interference. To
avoid radio frequency interference, do not use the Contour next
meter near electrical or electronic equipment that are sources of
electromagnetic radiation, as these may interfere with the proper
operation of the meter.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Contour NEXT and is the answer not in the manual?

Contour NEXT Specifications

General IconGeneral
Sample Size0.6 µL
Testing Time5 seconds
Memory Capacity800 test results
CodingNo coding required
Power SourceBattery
Measuring Range10 to 600 mg/dL
BatteryCR2032
Dimensions77 x 57 x 19 mm
Weight47.5 g
Operating Conditions5°C to 45°C
Storage Conditions-20°C