MiniWarden/PoolWarden + (PLUS) Operation Manual • www.poolwardentraining.com • 11
Default Readings Screen
The Default Readings Screen is displayed after power up and when a
button isn’t pressed for 2 minutes. It is the most critical screen as it will
display the current pH & ORP sensor readings, flow status, relay status,
alarm status and various symbols that are defined below. Menus within
PoolWarden are accessed through the Default Readings Screen. Please
review definitions of all Row & Column information and symbols below.
Row 1 (Column Header): The first row is a column header and
defines what you find below that particular column header. Example:
The “pH” Column Header on the first row means that the current pH
readings for Pool 1 (7.7) and Pool 2 (7.5) are just below.
Row 2 (Current Measurements Pool1): The current real time
measurements and status for Pool 1. Example for Pool 1: ORP=681,
pH=7.7, Temperature (Tf) = 75 degrees Fahrenheit, Flow switch 1 is
ON. The “a” on the far right indicates that Pool1 is in alarm.
Row 3 (Current Measurements Pool2, PoolWarden only): The current real time measurements and
status for Pool 2. Example for Pool 2: PPM = 3.2, ORP = 695, pH = 7.5, Temperature (Tf) = 102
degrees Fahrenheit, Flow switch 3 is ON and the alarm is not on for Pool2.
Row 4 (Relay Status): Row 4 displays the current status of all the relays in the following order with
symbols that are defined below (RlyP1 = Pool1 and P2 = Pool 2);
qPoolWarden Dual: RlyP1: ORP1, pH1, Aux1, Aux2 P2: ORP2, pH2, Aux3, Aux4
qPoolWarden Single: RELAY: ORP1, pH1, Aux1, Aux2
qMiniWarden: RELAY: ORP1, pH1
q_ : An underline indicates the relay is OFF and not in an active feed cycle. If there is no underline
for the Aux relay then the relay isn’t setup for control.
q: An Up arrow indicates the relay is ON and in an active feed cycle.
q: A Down arrow indicates the relay is OFF and in the OFF part of an active cycle.
qo : An "o" indicates the relay has reached the on time limit (overfeed limit) for the
day and will not turn on again until the overfeed limit clears automatically each night at midnight.
Note that cycling the power doesn’t clear the overfeed time. Select Clear Overfeed Times in the
service menu to reset the timer.
s : An "s" indicates the relay has reached the setpoint overfeed limit and will not turn on again until
the setpoint is achieved by other means (manually adding the required chemicals). Select Clear
Overfeed Times in the service menu to reset the timer.
qThe letter ‘b’ next to an ORP reading indicates ORP is in pH lockout and the feature of feeding
sanitizer at a fixed rate of minutes per hour is on (not available with TrueDPD or MiniWarden).
q The letter ‘p’ next to an ORP reading indicates ORP is in pH lockout and is off.
q
When the PoolWarden is turned on a time number will display on this line to the right which is a delay
before the relays will operate, the turn on delay gives time for accurate readings prior to controlling the
relays.
Other Symbols Defined:
qThe letter “a” on the right will display when the Pool alarm is on.
t Flow Status: The flow will either be ON or OFF with the standard flow sensor. Flow status for Pool 1
uses Flow 1 input for the sensor connection and Pool 2 uses Flow 3 input for the sensor connection on
the sensor circuit board. This cannot be changed.
qPool1: 1:2, Both flow switch 1 and 2 are on. 1:_, Flow switch 1 is on, 2 is off.
qMiniWarden with TrueDPD: 1:d, Flow switch 1 is on and 2 is used for TrueDPD commands.
qPool2 with TrueDPD: 3:d, Flow switch 3 is on and 4 is used for TrueDPD commands.
t PPM Display on Error: When the TrueDPD has an error the PPM is set to a high value so that it will
not start a sanitizer feed cycle. If that happens the PPM value will display as “—”.
PPM ORP pH Tf Flow
1.5 681 7.7 75 1:_a
3.2 695 7.5 102 3:d
RlyP1↑↓o P2_↓o 23%
PoolWarden+ Dual TrueDDPD
m
v
ORP pH Tf Flow
681 7.7 75 _:_a
RELAY↑↓o 23%
PoolWarden+ Single
m
v