MiniWarden/PoolWarden + (PLUS) Operation Manual • www.poolwardentraining.com • 13
Information Menus
PoolWarden has 6 information screens (handy, alarm, Langelier index, setpoint, special information and
TrueDPD) which are all accessible directly from the Readings Screen. The information screens are NOT
password protected.
Handy Menu
Press Down Arrow or Enter from the default readings screen.
qDaily Noon Data: Allows scrolling through the noon time readings beginning with the last
recording. The right and left arrow change the days. If the controller isn’t on at noon there will be no
reading saved.
qPast Data: This menu provides access to PoolWarden’s internally recorded data. The data can be
displayed visually on screen.
qBack - > Quit: Exit the Data and bring you back to the Data Recording screen.
q↑: Pressing the Up Arrow will jump forward 20 rows of data.
q>: Pressing the Right Arrow will move forward 1 data row at a time.
q<: Pressing the Left Arrow will move backward 1 data row at a time.
↓: Pressing the Down Arrow will jump backward 20 rows of data.
Relay Name pH v
OnToday 00:32:56
MonthOn 0000:32
Cnt 99 TMR 00:04:13
Relay Information
qEnter Measurements: The following manually taken pool
measurements: PPM, pH, ALK, Hardness and CYA can be entered
here. If PoolWarden is communication enabled then the data will be
sent / stored at www.PoolWarden.com with time stamps of when the
measurements were made.
qRelay Information: Displays current information about the relays. When a relay should be on and
isn’t turning on this screen helps to diagnose why the relay isn’t turning on.
qLine 1: Includes the name of the relay and the current status: “v” is in the off part of an active
cycle, “^” is in the on part of an active cycle, “_” not in an active cycle - relay is off. Press the
right and left arrows to switch relays.
Version 1.95
Updated On: 04/20/18
Serial Number 790860
05/02/18 11:51:42
On Cycles: 203
On Time: 157:02
Packets Sent: 284
Data Records: 1066
About Screen
qOnToday: The length of time the relay has been on today. This
can be cleared in the Service menu.
qMonthOn: The total hours and minutes the relay has been on for
the month.
qCnt: The time the relay has turned on in the day.
qTMR: The current cycle timer. If the relay should be on the timer
is typically counting, if not counting then refer to the relay setup
to see why it isn’t turning on.
qAbout Screen: List the total hours the unit has been on, total
number of power up cycles, data packets sent and other
information.
qEnter a Code: Allows for the entry of a factory code that can clear
the passwords or put the controller in a demonstration mode.
qStartup Screen:
qLine 1: Model - PoolWarden or MiniWarden
qLine 2: Name of the location if entered
qLine 3: The serial number and software date
qLine 4: Current date and time are displayed
PoolWarden+ Pool/Spa
Downtown Pool
SN:790860 04/30/18
05/02/18 12:00:15
Startup Screen