MiniWarden/PoolWarden + (PLUS) Operation Manual • www.poolwardentraining.com • 21
Main Menu - Security
Assign up to 4 passwords to the various personnel who will be working
with or servicing PoolWarden. The main menu is protected while the
Handy Menu, alarm screen and setpoints are not Password Protected.
There are 3 levels of access that are defined below. Scroll to the level and
assign up to a 6 digit password (numbers only) and press Enter to save.
Entering zero “0” will disable a password. The master password is required
if security is used.
Master: Access to all menus within PoolWarden including ability to
add, delete, or change passwords. If the password has been lost,
please read the troubleshooting section at the end of this manual.
Operator: Access to all menus except the Security menu.
Service: Access to the Service and quick ORP and pH.
Print Interval OFF
Print Data Now
Print Last 7 Days
Printer MAC Address
No Printer
Find Printer
Print Setup
Printer
Main Menu - Printer
Bluetooth receipt printers are supported. Make sure the printer is on and
select Find Printer - allow a couple minutes. Note: Multiple controllers can
share the same printer, if there are multiple in the room and you do not
want to use a specific printer turn it off first.
Once a day a header line will print with the name of the controller (setup in
the System Menu) and the serial number. Then at the appropriate intervals
the current measurements will be printed.
t Print Interval: Press Enter to cycle through OFF, 30 min, 60 min, 4 hrs
and Noon.
Software updating in the field is supported with an Internet connection.
Other methods include replacing the Micro SD hard drive or a memory
stick in a USB port.
t Select Check for Updates: Press the Enter button.
t Update To: If there is a new version the selection to update will be
displayed and press the Enter button to update. May take a couple
minutes depending on the connection.
t If there are no updates that will also be displayed.
t The controller will automatically re-start after the update.
Software Update
PoolWarden Ver 1.95
Date 05/08/18
_Check for Updates
Software Update
Master 0
Operator 0
Service 1 0
Service 2 0
Security Menu
t Print Data Now: Print the current measurements now.
t Print Last 7 days: Prints the last 7 noontime measurements. There may be less than 7 if the
measurements haven’t been made yet or if the controller was turned off at NOON on some of the
days.
t Printer MAC address: Will either show the printer MAC address or “No Printer”.
t Find Printer: Select to find the Bluetooth printer. Allow about a minute and make sure the printer is
on. If a MAC address is listed, this will display as “Remove Printer”.
t Print Setup: Print out the current configuration.
Service
Quick ORP
Quick pH
Service Level

Table of Contents

Related product manuals