MiniWarden/PoolWarden + (PLUS) Operation Manual • www.poolwardentraining.com • 20
Main Menu - Cyanuric Acid - CYA
ORP Is effected by cyanuric acid and during the day the ORP measurement
will drop and at night it will go up for the same chlorine and pH level if there is
cyanuric acid in the water. The higher the concentration the larger the ORP
change. At night the ORP increases and the controller will not feed any more
sanitizer until the sun comes up the next day, but during the night the actual
chlorine may drop so in the morning the chlorine level may be low. Increasing
the ORP setpoint at night will allow for sanitizer to still be fed even in the
presence of cyanuric acid.
t from Dusk Hour 0 PM: Use the CYA ORP setpoint from this hour at
night. Select from 0, 5, 6, 7, 8, 9, and 10 PM. Set to 0 to not adjust until
after midnight.
t ORP1: Enter the ORP setpoint for pool 1.
t ORP2: Enter the ORP setpoint for pool 2.
From Dusk Hour 0PM
Night time Setpoints
ORP 0
to Dawn Hour 0AM
CYA - Single Pool
From Dusk Hour 0PM
Night time Setpoints
ORP1 0 Orp2 0
to Dawn Hour 0AM
CYA - Dual Pools
t to Dawn Hour 0 AM: Continue in the morning until this hour. Select from 0, 5, 6, 7, 8, 9, and 10 AM.
Set to 0 to only adjust before midnight and not the morning.
In order to set this value observe the ORP reading at noon and midnight with the same sanitizer level, if
the cyanuric acid had no impact the ORP values would be the same.
When the ORP is being reduced, the status will be indicated in the info screen, press 4 from the readings
screen. If the hour matches the ORP will be reduced, if set to 10 AM, the ORP will be reduced until
10:59:59 AM.
Data Server Setup
Information
WIFI Connect
Software Update
Internet Menu
Main Menu - Internet
The MiniWarden+ and PoolWarden+ include built in WiFi, Ethernet and
Bluetooth. An Internet connection is required for accurate time and date. See
appendix G for connection information.
Data Server Setup
t Send Data Packet: Send data to the server to make sure it is working.
t Interval: The choices are 0 (no data), 15, 30, 60, 120 and 240 minutes.
Note: Data will be sent to the data server at the specified interval in line
with the actual time and stored into the internal database. Data recording is
based on this interval in the Internet setup.
t Start Hour: Enter the hour to start sending data. Use this feature if you
don’t want to send data at night.
Send a Data Packet
Interval 30 min
Start Hour 0
End Hour 0
On Alarm No
Data Server Setup
t End Hour: Enter the hour to stop sending data
t On Alarm: Send a data packet if the alarm turns on
Information
t Lan and WiFi MAC address: Some routers use the MAC address to grant access.
t Lan and WiFi IP address: The assigned IP address for both are listed.
WIFI Connect
t SSID: Enter the name of the network. Use a smart phone to list the available networks and to verify the
correct spelling. The limit is 20 characters.
t Pass: Enter the network password. The limit is 20 characters.
t Security: The type of security protocols is in the works.
t Update: Performs the following: save the setup, update the WIFI settings and re-start the controller. For
additional information refer to appendix G.