EasyManua.ls Logo

ControlOMatic POOLWARDEN Plus - Alarm Screen; Setpoints; Special Information; Langelier; Ryzner Index

ControlOMatic POOLWARDEN Plus
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MiniWarden/PoolWarden + (PLUS) Operation Manual • www.poolwardentraining.com • 14
Alarm Screen
Press Right Arrow from the readings screen to access the alarm menu. The alarm screen shows all the
conditions that are or will cause the alarm light to be on. If the alarm light is off and there are conditions
listed in the alarm screen then the alarm delay hasn’t been reached yet. The alarm delay requires the alarm
on condition to exist for a period of time before the alarm actually turns on.
Alarm conditions are set up in the Relay Setup Menu.
For the PoolWarden dual pool controller, press the Right Arrow a second time for the alarm conditions on
pool 2.
Setpoints
Press the 9 key from the readings screen to show current set-points.
Special Information
If there is anything to report there will be a “4” in the lower right corner of the readings screen. Press the 4
button to see the information.
t WIFI IP address will always be listed.
t If the ORP is being reduced from the cyanuric acid that will display
t If unable to connect to the Internet.
Langelier Index
Enter measurements
In the Handy menu
To enable the index
Langelier / Ryzner
Langelier / Ryzner Index
To enable, enter the Alkalinity and hardness in the Handy Menu, Enter
Measurements. To view the index, press the Up Arrow from the readings
screen. If either the Alkalinity or hardness are 0 the index will not display.
Press the up arrow again to cycle between indexes.
TrueDPD Information - Option
Press “6” for the TrueDPD information screen. Appendix F covers TrueDPD.
Quick Menus
Quick access to the most common settings for pH and ORP control. This is also password protected and
for the service password these limited settings can be changed.
t Press “2” from the readings screen for the Quick ORP Menu
t Press “3” from the readings screen for the Quick pH Menu
ORP1 Quick Settings
Acid Setpoint 7.5
MaxTime On 00:00:30
MinTimeOff 00:05:00
ORP1 Quick Settings
Acid Setpoint 7.5
MaxTime On 00:00:30
MinTimeOff 00:05:00
Press “3”
pH Relay Settings
ORP1 Quick Settings
ORP Setpoint 700
PPM Setpoint 2.0
MaxTime On 00:01:00
MinTimeOff 00:05:00
ORP2 Quick Settings
ORP Setpoint 700
PPM Setpoint 2.0
MaxTime On 00:01:00
MinTimeOff 00:05:00
Press “2”
Quick ORP with PPM

Table of Contents

Related product manuals