MiniWarden/PoolWarden + (PLUS) Operation Manual • www.poolwardentraining.com • 25
t Off If Time < 00:00:00: This command will keep the relay off if the time of
day is less than the value. Leave this at 00:00:00 if it doesn’t matter the
time of day to add water.
t Off If Time > 00:00:00: This command will keep the relay off if the time
of day is greater than the configured time setting. Leave this at 00:00:00 if
it doesn’t matter the time of day to add water.
t Off if Flow Off - none: The Aux Water Level Relay will be turned off if
“No Flow” is detected in the Flow Switch Input indicated.
t Overfeed 00:00:00: The Overfeed time represents the maximum amount
of time a Water Leveler can be on in a 24-Hour period from midnight to
midnight. Calculate the maximum amount of total time the Water Leveler would be on in a 24-Hour
period and enter the time here. The default time of 00:00:00 or disabled. This will prevent the possible
overflow situations.
Feed Daily Control Type
Feed Daily can be used to turn on a piece of equipment at the same time every day or specific days. It can
be used to perform the following:
qTurn on at a specific time and off at a specific time
qCan be enabled for any or all days of the week
qWhen it is on, it can also cycle on and off
t Manual Time 00:02:00: Manual turn on control.
t Day Of Week smtwtfs: Turn on for the selected days, if all letters for the days of the week are left lower
case, the relay will not turn on. To enable the relay to turn on select the Day of Week command and
press Enter, then select numbers 1 through 7 representing Sunday through Saturday and toggle
between the lower case and uppercase letter of the week. Lower case is disabled and uppercase
means the relay will be enabled or turned on on that day of the week.
Note: Internet is required for correct time and date.
t On If Time < 00:00:00: Turn the relay on when the time is less than the
value.
t On If Time > 00:00:00: Turn the relay on when the time is greater than
the value.
t MaxTimeOn 00:00:00: This command is used to cycle the relay on and
off continuously. Enter the desired on time for the cycle (such as 2 Hours
or 02:00:00) and press Enter to save the setting.
t MinTimeOff 00:00:00: When using MaxTimeOn, MinTimeOff must also
be set to complete the cycle. Once this off time has been reached the
relay will turn back on for the On Time.
ManualTime 00:02:00
DayOfWeek smtwtfs
On IfTime< 00:00:00
On IfTime> 00:00:00
MaxTime On 00:00:00
MinTimeOff 00:00:00
OffIfTime< 00:00:00
OffIfTime> 00:00:00
Off if Rly On none
Feed Daily
t Off If Time < 00:00:00: The relay will be off if the time is less than the value.
t Off If Time > 00:00:00: The relay will be off if the time is greater than the value.
t Off if Rly On none: The relay will of off if the indicated relay is on. This command is use full if there are
two pumps and only one should be on at the same time.
ManualTime 00:02:00
On if Flow On none
On if Flow Off none
OffIfTime< 00:00:00
OffIfTime> 00:00:00
On if Flow Off none
Overfeed 00:00:00
Water Level