The AC drive board ramps up the oven fan motor (M1) Counter-clock
wise for 2 minutes.
If Voltage is sent from terminal 10 on Connector X14 on the control board to
terminal M on the AC drive board the fan will turn in reduced speed.
NOTE: If the door switch (S7) opens by the door opening, then the fan circuit
is de-energized.
c The hot air heat circuit is energized
220 VAC is sent from terminal 3 of connector X12 on the Control Board
(A10) to the coil of Contactor K4 until the cabinet reaches the set temperature
as sensed at probe B6.
The contactor K4 closes and 220 VAC is sent to the element (E4)
d The steam circuit is e
nergized
220 VAC is sent from terminal 4 of connector X12 on the Control Board
(A10) to the coil of the Y4 solenoid allowing water to be thrown against the
element for 25 seconds every 40 seconds.
NOTE: If the set temperature is above 212 degrees F the hot air circuit will be
energized until the compartment setting is reached and the solenoid will be
energized 12 seconds every 40 seconds..
e When the condensate box is heated to 140 degrees F at the B3 probe, 220 VAC is
sent from terminal 5 of connector X12 to the condenser valve (Y1) until the
temperature drops.
f When the Pre-heat timer counts to 0
The alarm sounds until the operator opens the door.
The Steam cycle begins and the process starts at 3-b again until the Cook
timer counts to 0.
4 With the combi in the Hot Air mode with time on the timer, the door closed and the
start icon is depressed
a The front display will include a Thermometer while the unit preheats.
b The fan circuit is energized
Voltage is sent from terminals 7 and 9 on connector X14 on the Control Board
to the terminals S and R respectively on the AC drive board for 2 minutes.
The AC drive board ramps up the oven fan motor (M1) Clock wise for 2
minutes.
Voltage is
removed from the AC Drive for 15 Seconds
Voltage is sent from terminals 7 and 8 on connector X14 on the Control Board
to terminals S and F respectively on the AC drive board for 2 minutes.
The AC drive board ramps up the oven fan motor (M1) Counter-clock
wise for 2 minutes.
If Voltage is sent from terminal 10 on Connector X14 on the control board to
terminal M on the AC drive board the fan will turn in reduced speed.
NOTE: If the door switch (S7) opens by the door opening, then the fan circuit
is de-energized.
c The hot air heat circuit is energized
63