CTS4 short circuit
to earth
•
Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
Steam generator
operating fault (No
temperature
increase in the SG
within 3 mins. by
>5°C on the B3
sensor)
•
Immersion heater defective
•
Heater contactor defective
•
Calcified B3 sensor
SG pump error
Pump does not
start (double level
sensor does not
reach lower level
within 20 secs.)
•
Pump defective (M4)
•
Pump blocked / contaminated
•
Water level sensor has short circuit to earth
due to calcification
•
Filling gap of the area touching the water is
calcified together with the double level
sensor
Invalid cooking
algorithm
•
The cooking programme is not recognised
•
Old software version
•
Wrong entry in the recipe data bank
Data in IDM
module not valid
•
IDM defective
•
Checksum faulty ! Disconnect appliance
from mains for 10 secs. and restart
Communication
error
Connection faulty
between control
module and
operating module
•
Interface cable between control module and
operating module interrupted
•
Plug on the control module or operating
module loose
•
Communication between CM and OM
disturbed briefly ! Disconnect appliance
from mains for 10 secs. and re-start
•
Wrong software on the control module (for
et)
•
Control module defective (for et)
Communication
interface to CM
was unable to be
opened
•
Initialisation error for COM interface !
Disconnect appliance from mains for 10
secs. and re-start
General
initialisation error
•
Disconnect appliance from mains for 10
secs. and restart
15 - 21