5.14: Completion Steps
5.14.1: Objective
Save the work and perform additional testing with load and under normal control source.
5.14.2: Steps
5.14.2.1 On the Main screen, click Save to Flash ( ).
5.14.2.2 Remove AC power from connector J1.
5.14.2.3 Attach load.
5.14.2.4 Reconnect AC power to connector J1.
5.14.2.5 Re-tune velocity and position loops if applicable.
5.14.2.6 On the Main screen, click Save to Flash ( ).
5.14.2.7 On the Main screen, click Save to Disk ( ) (for backup or duplication).
5.14.2.8 Click Control Panel ( ) and then click Reset
OR
Power-cycle the amplifier.
5.14.2.9 The amplifier tuning procedure is complete.