Regen Resistor Sizing and Configuration Xenus XSL User Guide
158 Copley Controls Corp.
A.2: Configuring a Custom Regen Resistor
A.2.1: Regen Configuration Objective and Warning
Configure the amplifier to operate properly with the custom resistor.
Incorrect values may damage amplifier or external regen resistor.
!
WARNING
For the regen I
2
T algorithms to work correctly, the values entered in the following
steps must be correct. Damage to the external regen resistor may result from
incorrect values entered. Damage to the amplifier may result if an incorrect
resistance value is entered.
Failure to heed this warning can cause equipment damage.
A.2.2: Regen Configuration Instructions
A.2.2.1 On the Main screen, click Configure Regen ( ) to open the Regen
Resistor screen.
A.2.2.2 Select Custom Resistor and then click Configure to open the Custom Regen
Configuration screen.
A.2.2.3 Enter a Resistance within the range described on the screen. Click Next for Step 2.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com