Specifications Xenus XSL User Guide
56 Copley Controls Corp.
3.21: Power Dissipation
Model:
Output Power Mains Voltage
XSL-230-18
XSL-230-18-R
XSL-230-36
XSL-230-36-R
XSL-230-40
XSL-230-40-R
120 Vac 30 W 55 W 92 W Maximum
Continuous
240 Vac 40 W 75 W 120 W
Power Dissipation
0
20
40
60
80
100
120
0 5 101520
Continuous Output Current (A)
Power Dissipation (W)
230 VAC
120 VAC
3.22: Thermal Impedance
See Thermal Considerations (p. 169).
3.23: Mechanical and Environmental
Size 7.55 in (191,8 mm) X 5.57 in (141,5 mm) X 2.57 in (65,3 mm)
Weight
Without Heat Sink
With Heat Sink XSL-HL
With Heat Sink XSL-HS
3.0 lb (1.36 kg)
4.3 lb (1.95 kg)
4.8 lb (2.20 kg)
Ambient Temperature
Storage
Operating
-40 to +85°C
0 to +55°C
Humidity 0% to 95%, non-condensing
Contaminants Pollution degree 2
Environment IEC68-2: 1990
Cover Material
Meets U.L. Spec 94 V-0 Flammability Rating
Cooling Heat sink and/or forced air cooling required for continuous power output