Xenus XSL User Guide Quick Setup with CME 2
Copley Controls Corp. 95
5.8.2: Standard Digital Outputs
5.8.2.1 Click the Digital Outputs tab of the Input/Output screen.
Lo/Hi: Indicates current state of output.
Red light: output is active.
Grey light: output is not active.
5.8.2.2 Choose any of the following functions for any output. OUT4 is recommended for brake
function.
Output Function Description For More Information
Not Configured No function assigned. Output
remains high.
Fault Active High Output goes high when at least
one fault is detected.
Fault-Active Low Output goes low when at least one
fault is detected.
Faults (p. 36).
Brake-Active High Output goes high to activate the
brake.
Brake-Active Low Output goes low to activate the
brake.
Brake Operation (p. 33).
PWM Sync Output
(OUT1 only)
The PWM synchronization output. PWM Sync Input (p. 43) and
PWM Sync Output (p. 44).
Custom-Active High The output goes high when one or more of the triggering events are
detected.
To set the triggering events, see Custom Digital Outputs (p. 96).
Custom-Active Low The output goes low when one or more of the triggering events are
detected.
To set the triggering events, see Custom Digital Outputs (p. 96).
Program Control High Output state controlled by CVM or CAN program
Program Control Low Output state controlled by CVM or CAN program