Wiring Xenus XSL User Guide
64 Copley Controls Corp.
4.4: Regen Resistor (J3) (Optional)
Mating Connector
Description Euro-style, 5 position, 5.0 mm pluggable male terminal block.
Manufacturer PN Wago 721-605/000-043
Wire Size 22 - 14 AWG
Recommended Wire 14 AWG, 600 V
(Shielded cable used for CE compliance)
Wire Insertion/Extraction Tool Wago 231-131
Standard connector and tool are included in connector kit XSL-CK or XSL-CA
Pin Description
Pin Signal Function
1 Regen + + DC Bus to one side of regen resistor
2 N/C No connection
3 Regen - Collector of regen transistor to one side of regen resistor
4 N/C No connection
5 Ground Enclosure ground and cable shield
Regen Resistor Wiring Diagram
Regen
+
Regen
-
+
DC Bus
-
DC Bus
Fus es
Regen
Resistor
Enclosure
Amplifier J3
J3-5
J3-4
J3-3
J3-2
J3-1
Regen Resistor Fusing
Recommended Fuses:
Regen Resistor Fuse type
XSL-RA-01 Cooper Bussman KLM-8 or equivalent
XSL-RA-02 Cooper Bussman KLM-12 or equivalent
User Supplied See Regen Resistor Sizing and Configuration (p. 153).