Using CME 2 Xenus XSL User Guide
134 Copley Controls Corp.
6.5: Scope Tool
6.5.1: Scope Tool Overview
The CME 2 Scope Tool can be used to tune the amplifier, monitor amplifier performance while in normal
operation, and to perform diagnostics. The Scope’s Function Generator and
Profile Generator can be used to drive the motor without using an external control source. The Auto Set Up
feature automatically sets all the scope parameters for the most commonly used tuning scenarios.
Click the Scope tool (
) to access the tool and open the Oscilloscope window.
Scope Screen
Function/Profile
Generation
Scope and
control loop
settings
Scope
controls
Here are general procedures for performing basic activities with the scope.
To Run a Function Generator Move:
1 Click on the Function Generator tab.
2 As required, adjust Function Generator settings, scope tool settings, gains, limits,
and parameters (as described in the following sections of this chapter).
3 Click Start to begin move and trace. Click Stop to stop the move.
To Run a Profile Move:
1 Click on the Profile tab.
2 As required, adjust Profile settings, scope tool settings, gains, limits, and
parameters (as described in the following sections of this chapter).
3 Click Start. Click Stop to stop the move.
To Monitor Externally Controlled Motion:
1 As required, adjust scope tool settings.
2 Click Record to begin trace. Click Stop Trace to stop the trace recording.
3 Begin move with external controller.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com