EasyManua.ls Logo

Copley Controls Xenus XSL - Page 104

Copley Controls Xenus XSL
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Xenus XSL User Guide Quick Setup with CME 2
Copley Controls Corp. 103
5.9.3.4 Enter the options described below:
Option Description For More Information
Max
Velocity
Maximum trajectory velocity. Max value may
depend upon the back EMF and the Max
feedback count. Min:0.
Default: 0.25 x motor velocity limit.
Max Accel Maximum trajectory acceleration. Max value may
depend upon the load inertia and peak current.
Min:0.
Default: 0.5 x velocity loop Accel. Limit value.
Max Decel Maximum trajectory deceleration. Max value may
depend upon the load inertia and peak current.
Min:0. Default: 0.5 x velocity loop Accel. Limit
value.
Position Mode and Position Loop (p. 24)
Abort
Decel
Deceleration rate used by the trajectory
generator when motion is aborted. Min:0.
Default: 0.5 x velocity loop Accel. Limit value.
See Brake Operation (p. 33)
5.9.3.5 Click Close.
5.9.3.6 Click Save to Flash ( ).
5.9.3.7 Proceed to Auto Phase (p. 105).