Using CME 2 Xenus XSL User Guide
136 Copley Controls Corp.
6.5.3: Scope Settings
The settings accessible from the screen and tabs shown below affect the operation of the scope.
Channel Trace Variable Options (Chan 1-4)
To choose which trace variable to display in a scope channel, click the channel button (such as
). Then choose a category, and then a trace variable.
The categories and variables are listed below.
Category Trace Variable Category Trace Variable
Disabled <Channel disabled, no
associated variable>
Position Commanded Position
Limited Position
Actual Position
Following Error
Current Commanded Current
Actual Current
Acceleration Profile Acceleration
Velocity Profile Velocity
Commanded Velocity
Limited Velocity
Actual Velocity
Velocity Error
Voltage Analog Command
Bus Voltage
Analog sin Input
Analog cos Input