Operational Theory Xenus XSL User Guide
34 Copley Controls Corp.
2.9: Status Indicators
2.9.1: Amplifier and CAN Interface Status Indicators
The amplifier’s status indicator is a bicolor LED labeled STATUS on the amplifier front panel. The
CAN interface status indicator is a bicolor LED labeled CAN. Locations are shown below.
Xenus Status Indicator
CAN Status Indicator
CNTRL
J4
J3
J2
J1
STATUS
RS232
C
AN
ADDR
J5
S1
J6
J7
J8
FDBCK
+24V
BRAKE
R
TN
REGEN+
U
V
W
L1
L2
L3
CAN
Xenus
™
REGEN-
FDBCK
+24V
BRAKE
RTN
2.9.2: Amplifier Status Indicator Operation
Amplifier status indicator color/blink codes are described below.
Color/Blink Code Meaning
Not illuminated No +24 Vdc power to amplifier.
Steady green Amplifier is enabled and operational.
Slow-blinking green Amplifier is disabled. No faults or warnings are active.
Fast-blinking green A limit switch is active. The amplifier is enabled.
Steady red A non-latched fault has occurred.
Blinking red A latched fault has occurred.
20 Fast red blinks on
power up or reset
Amplifier has reverted to boot mode.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com