2C9
1-4-7
U020
Initializing all data
Description
Initializes all the backup RAM on the main board to return to the original settings.
Purpose
Run as needed.
Method
1. Press the start key.
2. Select "on" using the zoom +/- keys.
3. Press the start key. All data in the backup RAM is initialized, and the original settings for Japan specifi-
cations are set.
When initialization is complete, the machine automatically returns to the same status as when the main
switch is turned on.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
U021
Initializing memories
Description
Initializes the setting data other than that for adjustments due to variations between respective machines, i.e.,
settings for counters, service call history and mode settings. As a result, initializes the backup RAM according
to the specifications depending on the destination selected in U252.
Purpose
Used to return the machine settings to the factory settings.
Method
1. Press the start key.
2. Select "on" using the zoom +/- keys.
3. Press the start key. All data other than that for adjustments due to variations between machines is initial-
ized based on the destination setting. When initialization is complete, the machine automatically returns
to the same status as when the main switch is turned on.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key. The indication for
selecting a maintenance item No. appears.
Maintenance
item No.
Description
Display Operation
- - - Canceling initialization
on Executing initialization
Display Operation
- - - Canceling initialization
on Executing initialization