EasyManua.ls Logo

Corghi 601 - TROUBLESHOOTING

Corghi 601
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
56 Operator’s manual @ 601
TROUBLESHOOTING
No visualization on the display after switching on
External power supply malfunction
➥ Check the external power supply
Power supply card malfunction
➥ Replace the power supply card.
Loose connection between the computer and power supply cards
➥ Check the connector on the connection line
Computer card malfunction
➥ Replace the computer card
The display is normal, but the start switch and buttons A, L and D
for data entry are not working
Loose connection between the computer and power supply cards
➥ Secure the connection line between the computer and power supply cards
Computer is out of service
➥ Re-start the machine
The display is normal, but the brake is not working
Incorrect switch connection
➥ Open the cover and secure the touch-sensitive switch connector
Power supply card malfunction
➥ Replace the power supply card.
Computer card malfunction
➥ Replace the computer card
The machine start-up takes a long time, the brake is not working
and balancing is not accurate.
The machine body is positioned on an unstable plane
➥ Solve the problem according to the test results
Cone or quick fixing cap effect
➥ Re-tighten the quick fixing cap.
The wheel is not mounted correctly
➥ Check the power supply.
The power supply inside the machine is unstable
➥ The operator can regulate the power supply.
Power voltage fluctuates considerably
➥ Replace the computer board if necessary.
Calibration value has changed
➥ Re-calibrate according to the User’s Manual.
Value inside the machine has changed
➥ Enter the dis, In-I and SFA data again according to the instructions on the ma-
chine, then calibrate again to make sure that the machine is working correctly

Table of Contents