Operator’s Manual (PRELIMINARY)
Publication Number: 621260373OPR - 8 - © 2008, IMI Cornelius Inc.
Figure 7
Type 2 BIB Syrup Connections
Refer to Table 6 and Figure 8 when replacing a Type 2 BIB container.
Figure 8
Unit Connector
Bag Connector
(Red - Female)
(White - Male)
Syrup Tube
Table 6
Step Procedure
1. Push in on the outer connector tab and pull the syrup hose and stub out to
unlock the connector from the BIB.
2. Pull the connector sideways to disengage the line from the bag connector.
3. Place a new BIB on the rack and open the cardboard flap. Be careful not
to puncture the bag with any sharp objects.
4. Pull the bag connector out of the box and remove the dust cap.
5. Rinse the QCD connector in warm water.
6. Re-install the QCD connector onto the new BIB connector by slipping it
onto the connector and pushing the syrup hose and stub down toward the
box. Important! Button should be flush, as shown in Figure 8.
Bag Connector
Stub
Syrup Tube
Connector Tab