Service settings manual J5060403 v1.2
Settings for heat sources :
Para-
meter
Function Parameter description
Setting
range
Default value
S3.1
MAXIMUM BOILER TEMPERATU-
RE
Setting of maximal boiler temperature.
60 ÷ 160 °C
90
S3.2
BOILER TEMPERATURE INCRE-
ASE FOR MIXING CIRCUIT
Setting of difference between boiler temperature and
calculated stand-pipe temperature.
0 ÷ 25 K
5
FLOOR DRYING PARAMETERS
Floor drying parameters :
Para-
meter
Function
Setting
range
Default
value
F1.1 ACTIVATION OF FLOOR DRYING
0- NO
1- YES
0
F1.2 INTERVAL 1: DURATION
1 ÷ 15 days
10
F1.3 INTERVAL 1: START TEMPERATURE
10 ÷ 60 °C
20
F1.4 INTERVAL 1: END TEMPERATURE
10 ÷ 60 °C
20
F1.5 INTERVAL 2: DURATION
1 ÷ 15 days
5
F1.6 INTERVAL 2: START TEMPERATURE
10 ÷ 60 °C
20
F1.7 INTERVAL 2: END TEMPERATURE
10 ÷ 60 °C
50
F1.8 INTERVAL 3: DURATION
1 ÷ 15 days
10
F1.9 INTERVAL 3: START TEMPERATURE
10 ÷ 60 °C
50
F1.10 INTERVAL 3: END TEMPERATURE
10 ÷ 60 °C
50
F1.11 INTERVAL 4: DURATION
1 ÷ 15 days
5
F1.12 INTERVAL 4: START TEMPERATURE
10 ÷ 60 °C
50
F1.13 INTERVAL 4: END TEMPERATURE
10 ÷ 60 °C
20
The procedure for setting floor drying parameters is the same as for the
service settings (see page 32).
In group F1 are parameters for floor drying: