25
5.9 Parameter Password Lock Function
The password lock parameter value follows the 421 code rule:
Lock
parameter
1: Locked
0: Unlocked
1
1
1
1
1
1
1
1
1
1
1
1
Password
value range
(summation)
Example 1
Example 2
Example 3
multiplication
factor
0 00 1
0
4
4
4
4
0~7
(1st digit of password value)
0~7
(2nd digit of password value)
0~7
(3rd digit of password value)
0~7
(4th digit of password value)
0 0 0 00
0
0 0 0
0
0
1*1=1
1*1=1
1*4+1*2+1*1=7
1*1=11*4=4
2
2
2
2
0 0 0 01
1
1
1
0 0 0 0
0 0 0 0
0 0 1 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 1
0 0 0 1
0 1 1 1
The controller can lock key parameters to prevent users from misoperation. The
parameters marked with "*" in the parameter table can be locked with the parameter
password lock.
8
8
8
8
Long press and ▲ to enter the advanced parameter interface.
▲ or ▼ to switch to
Press and to Adjust parameter values.
After setting the parameter password, exit the current interface and enter again, you
can see that the parameter value disappears.
8 Enter the advanced parameter interface, switch to , enter the previously entered
password, you can see the disappearing set password parameter, and then change
the password.
Short press ., which is used to set the password.
Maximum output voltage
limit
Output Frequency
Example 1: To lock the output frequency, 12 groups of binary codes are 000000000001, and the set password value is 0001.
Example 2: Lock the output frequency, sensor type and the second signal source of control output, 12 groups of binary codes
are 100001000001, and the set password value is 4101.
Example 3: Lock output frequency, the first signal source of main output and the second signal source of main output, 12
groups of binary codes are 000000000111, and the set password value is 0007.
When "Password Lock Parameter Range" is set to 9999, all parameters marked with "*" will be locked.
The first signal source of
Main output
Control Output Type
Sensor Type
Logic operation of signal
sources of Main output
The first signal source of
Control output
The second signal source of
Control output
The second signal source of
Main output
The third signal source of
Main output
The third signal source of
Control output
Logic operation of signal
sources of Control output
SDMC20-S
SDMC20_SMS-EN_2.01
Digital Single Phase Asynchronous Motor Controller
2023-11