EasyManuals Logo

Curtis 1244 User Manual

Curtis 1244
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
26
Curtis 1244 Manual, Rev. E
3 — PROGRAMMABLE PARAMETERS: Acceleration Parameters
M1–M4, ACCEL RATE
e acceleration rate defines the time it takes the controller to accelerate from
0% output to 100% output. A larger value represents a longer acceleration
time and a gentler start. Fast starts can be achieved by reducing the acceleration
time, i.e., by adjusting the accel rate to a smaller value. e acceleration rate is
adjustable from 0.1 second to 5.0 seconds, in 0.1 second increments. It can be
set independently for each of the four operating modes.
M1–M4, BRAKE RATE
e braking rate defines the time it takes the controller to increase from 0%
regen braking current to 100% regen braking current when braking is requested.
A larger value represents a longer time and therefore a gentler increase in braking
strength. Full braking strength is achieved more quickly when the braking rate
parameter value is reduced. e braking rate is adjustable from 0.1 second to
5.0 seconds, in 0.1 second increments, and can be set independently for each
of the four operating modes.
DECEL RATE
e deceleration rate defines the time it takes the controller output to respond
to a decrease in applied throttle. e deceleration rate defines the vehicle’s braking
characteristic for any reduction in throttle, including to neutral, that does not
include a request for the opposite direction. It also defines the characteristic for
braking after Emergency Reverse is released. e decel rate is adjustable from 0
to 10 seconds, in 0.1 second increments. e decel rate works in conjunction
with the throttle braking percent parameter, which must be set greater than zero
for the programmed decel rate to be active. e decel rate is not a MultiMode™
parameter, and its value will therefore aect all four operating modes.
QUICK START
e quick start function provides faster than normal acceleration in response to
fast changes in throttle demand. Upon receiving a sudden high throttle demand
from neutral, the quick start function causes the controller to exceed its normal
acceleration rate. e quick start algorithm is applied each time the throttle
passes through neutral and the controller is not in braking mode. Quick start
is adjustable from 0 to 10, in increments of 1. Increasing the value “livens” the
vehicles acceleration response to fast throttle movements.
Acceleration Parameters